A recessed step light can have two sets of dimensions that look equally plausible in a lighting schedule. One describes the fixture. The other describes the opening. A specification writer can copy the right numbers from the catalogue and still put them in the wrong column.
Which dimensions belong in the site-opening column?
Use the cutout dimensions or the approved installation drawing for the exact version being ordered. Keep visible fixture dimensions and sleeve dimensions in separate fields. When the catalogue gives only the fixture body size, flag the opening for confirmation and ask for a drawing before issuing the schedule.
| Catalogue example | What the entry supplies | What to put in the schedule |
|---|---|---|
| Recessed Outdoor LED Step and Wall-Mounted Guide Light | Visible dimensions of 162 × 100 × 58 mm for the 5 W version and a separately listed 153 × 54 × 56 mm cutout. | Keep the two sets of dimensions in their own columns. Ask for the drawing that matches the ordered version before preparing the opening. |
| Linear LED Inground Light | Fixture body dimensions for several lengths. | Use the body dimensions for the model comparison. Request the sleeve drawing for the selected length before entering sleeve dimensions. |
Recheck the exported schedule
Check the exported CSV that the buyer or installer will actually use. A table on the website and a downloaded copy can carry different values after an edit. For each row, retain the model or configuration, the catalogue or drawing reference, and a note for any field that the supplier still needs to confirm.
For a worked example, take two sample lines for the 10 W Open-Frame LED Bollard, with four and two fixtures. The baseline nominal load is 60 W. If the first quantity changes to seven, its line total should change from 40 W to 70 W and the batch to 90 W. A requested height of 500 mm also needs confirmation because the listed heights are 400 mm and 600 mm. The calculation is a check on the schedule; driver and circuit design require their own review.
Four checks before issuing the file
- Match each row to a model and the intended version.
- Separate body, cutout and sleeve dimensions.
- Recalculate totals after a quantity or wattage changes.
- Open the delivered CSV and follow its source links. Mark unconfirmed fields before forwarding it.
If a drawing or configuration is missing, send Veilumen the model, the schedule line and the field you need verified. That lets the supplier review the exact version before you issue the specification.